Features
Keyless entry codes ........................................................................................................
Relay activation time in sec (00-99, 00 = 0.5 sec, factory set to 05) ................................
Relay activation code (0-9*, 00-99, or QQ, factory set to QQ) .........................................
Security code (factory set to 845464) .............................................................................
To enter a Q (relay activation or keyless entry codes only)** ...........................................
Timed dialing mode (factory setting) ...............................................................................
No dialing mode ..............................................................................................................
Keyless entry/ringdown hang-up enabled (factory setting) .............................................
Keyless entry/ringdown hang-up disabled ......................................................................
Unlimited dialing mode ...................................................................................................
Exit programming ...........................................................................................................
Restore all programming to factory defaults ...................................................................
1-6 digits
2 digits
1-2 digits
6 digits
QQ
Q1
Q2
Q3
Q4
Q5
##7
###
#00 - #31
#40
#41
#47
* When a single digit relay activation code is programmed (0-9), the activation touch tone must be held for a minimum of 100 msec. Most cell phones
and some cordless phones produce short touch tones below 100msec in length regardless of the length of time the digit is held, it is recommended
to use a 2-digit activation code in these situations.
** Entering a
Q
uses one digit location and can only be used in the relay activation code or keyless entry codes.
Note: A double beep indicates a valid complete entry; three beeps indicate an error or that you are leaving the programming mode.
D. Quick Programming Features
Memory
Location
Enter Digits
- then -
+
+
+
+
To Program the SRC-1 to...
...operate the doorstrike for 2 seconds
...activate the doorstrike when touch tones “QQ“ are detected
...activate the doorstrike when touch tone “6” is detected
...not allow the entry device to dial through the unit
Enter Digits:
0 2 # 4 0
Q Q Q Q # 4 1
6 # 4 1
Q 2
E. Programming Examples
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries
assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.
DOD# 176
Printed in the U.S.A.
P
P
r
r
o
o
d
d
u
u
c
c
t
t
S
S
u
u
p
p
p
p
o
o
r
r
t
t
L
L
i
i
n
n
e
e
.
.
.
.
.
.
7
7
1
1
5
5
.
.
3
3
8
8
6
6
.
.
8
8
6
6
6
6
6
6
F
F
a
a
x
x
B
B
a
a
c
c
k
k
L
L
i
i
n
n
e
e
.
.
.
.
.
.
7
7
1
1
5
5
.
.
3
3
8
8
6
6
.
.
4
4
3
3
4
4
5
5
ZF302690 Rev C
O
O
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
This mode is used when the entry device needs to dial to connect to the secure phone. Going off-hook with the entry device starts
a 5 second timer that is restarted by any touch tone* until timed out. After the timer has timed out, the next touch tone will be inter-
preted as the first digit of the relay activation code, and will disconnect the entry phone.
*If the relay activation code is set to QQ, a Q dialed at any point will stop the timer and be interpreted as the first digit of the relay
activation code.
A. Q1 Mode (Timed dialing, any relay activation code)
This mode is used when the entry device doesn’t need to dial to connect to the secure phone. The first touch tone detected will be
interpreted as the first digit of the relay activation code, and will disconnect the entry phone.
B. Q2 Mode (No dialing, any relay activation code)
A momentary closure across terminals 5 and 6 will activate the relay for the programmed time. If the closure is longer than the pro-
grammed relay activation time, the relay will remain activated until the closure is released.
E. Trigger Input
This mode ignores all touch tones until a Q is detected, which is interpreted as the first digit of the relay activation code, and will
disconnect the entry phone. If this mode is selected, the activation code will be set to QQ and you will be unable to change it.
C. Q5 Mode (Unlimited dialing, QQ relay activation code only)
If keyless entry / ringdown hang-up is enabled, and the first touch tone dialed is #, the unit will disconnect the secure phone and lis-
ten for a keyless entry code from the entry phone. The unit will also provide talk battery to the entry phone for 2 seconds after a
CPC to prevent a false off-hook if installed on a ringdown extension.
D. Keyless Entry / Ringdown Hang-Up (Enabled with Q3)
Vista de pagina 3
1 2 3 4

Comentarios a estos manuales

Sin comentarios