3
BBAASSIICC SSPPEECCIIFFIICCAATTIIOONNSS AANNDD DDIIMMEENNSSIIOONNSS
FFrreeeessttaannddiinngg SSiiddee--BByy--SSiiddee RReeffrriiggeerraattoorr//FFrreeeezzeerr
DDEESSCCRRIIPPTTIIOONN VVCC//DDDDSSFF
Overall Width 35 5/8” (90.5 cm)
Addition of side panels: 35 7/8” (91.1 cm)
Overall Height from Bottom 70” (178.0 cm)
Addition of tops/grilles: 71 7/8” (182.6 cm)
Overall Depth from Rear To front of door: 26 3/4” (67.9 cm)
Cutout Width 36” (91.4 cm)
Cutout Height 70 1/2” (179.0 cm)
Addition of tops/grilles 72” (182.9 cm)
Cutout Depth 24” (61.0 cm)
Electrical Requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded
3-prong plug attached to product.
Maximum Amp Usage Non-Dispenser - 7.8 amps Dispenser - 9.4 amps
Inlet Water Requirements 1/4” copper tubing inlet waterline; minimum 35 psi; maximum 100 psi
Overall Interior Capacities Dispenser Units
Non Dispenser Units
•Refrigerator 13.5 cu. ft. (382 liters) 13.5 cu. ft. (382 liters)
•Freezer 8.1 cu. ft. (229 liters) 8.0 cu. ft. (226 liters)
•Total Capacity 21.6 cu. ft. (611 liters) 21.5 cu. ft. (608 liters)
Approximate Shipping Weight 314 lbs. (141.3 kg)
DANGER
RRiisskk ooff CChhiilldd EEnnttrraappmmeenntt
BBEEFFOORREE YYOOUU TTHHRROOWW AAWWAAYY YYOOUURR OOLLDD
RREEFFRRIIGGEERRAATTOORR OORR FFRREEEEZZEERR::
•Take off the doors.
•Leave the shelves in place so that children
may not easily climb inside.
IIMMPPOORRTTAANNTT::
Child entrapment and
suffocation are not problems of the past.
Junked or abandoned refrigerators are still
dangerous... even if they will sit for “just a few
days.”
IItt iiss tthhee ccuussttoommeerr’’ss rreessppoonnssiibbiilliittyy ttoo::
•contact a qualified electrical installer.
•assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA
70-latest edition or Canadian Electrical Code C22.1-1998 and C22.2 No. 0-M91 (or latest edition), and all local codes
and ordinances. (115 volt, 60-Hz, 15 amp, fused, electrical supply is required. It is required that a separate circuit
serving only this appliance be provided. This appliance is equipped with a power supply cord having a 3-prong
grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong, grounding-
type wall receptacle. If a 2-prong receptacle is encountered, the customer must contact a qualified electrical installer
to have it replaced with a properly grounded 3-prong receptacle. Do not use an extension cord or adapter plug.)
EELLEECCTTRRIICCAALL SSHHOOCCKK HHAAZZAARRDD
PPlluugg iinnttoo aa ggrroouunnddeedd 33--pprroonngg oouuttlleett..
DDOO NNOOTT rreemmoovvee ggrroouunndd pplluugg..
DDOO NNOOTT uussee aann aaddaapptteerr..
DDOO NNOOTT uussee aann eexxtteennssiioonn ccoorrdd..
FFaaiilluurree ttoo ffoollllooww tthheessee iinnssttrruuccttiioonnss
ccoouulldd rreessuulltt iinn ffiirree oorr eelleeccttrriiccaall sshhoocckk..
WARNING
Power cord with 3-prong
grounding plug
Grounding-type wall
receptacle
**WWhheenn iinnssttaalllliinngg iinnttoo aa ccuuttoouutt,, tthhee eeddggee ooff tthhee ddoooorr mmuusstt bbee 22 77//88”” ((77..33 ccmm)) ffffrroomm tthhee aaddjjaacceenntt ccoouunntteerrttoopp//ccaabbiinneett..