LDB-2
LDB-2
Ring/Loop
Detector
December 15, 2011
The LDB-2 Ring/Loop Detector monitors an analog phone line
for ringing or an in-use condition. A built-in relay can be activat-
ed when either of these conditions are detected. This is ideal for
monitoring line status or for providing a visual indication of such.
When monitoring for ring, an internal pot can be adjusted to
allow the relay closure to stay on steady, or follow standard ring
cadence.
The LDB-2 comes complete with a 12 VDC power adapter, and
can also provide 12V DC power through its auxiliary 12V DC
output terminals.
Provide a Contact Closure on Ringing
or Off-Hook
P
P
h
h
o
o
n
n
e
e
.
.
.
.
.
.
7
7
1
1
5
5
.
.
3
3
8
8
6
6
.
.
8
8
8
8
6
6
1
1
i
i
n
n
f
f
o
o
@
@
v
v
i
i
k
k
i
i
n
n
g
g
e
e
l
l
e
e
c
c
t
t
r
r
o
o
n
n
i
i
c
c
s
s
.
.
c
c
o
o
m
m
h
h
t
t
t
t
p
p
:
:
/
/
/
/
w
w
w
w
w
w
.
.
v
v
i
i
k
k
i
i
n
n
g
g
e
e
l
l
e
e
c
c
t
t
r
r
o
o
n
n
i
i
c
c
s
s
.
.
c
c
o
o
m
m
• Detects ring voltage and loop connect
• Screw terminal connections
• Wall mountable with foam tape (included) or
screws (not included)
Auxiliary 12V DC output
Adjustable time-out for relay closure
• Two sets of relay contacts provided
• Selectable NO (normally open) or NC (normally
closed) relay contacts
• Limited one year warranty
• Control a strobe light for ring indication
• Provide relay closures on ring and off-hook
• Trigger a security camera
• Trigger a tape recorder
• Phone “In Use” indicator
Power: 120V AC to 12V DC adapter provided
Dimensions: 74mm x 53mm x 25mm (2.9” x 2.1” x 1.0”)
Shipping Weight: 0.4 kg (0.86 lbs)
Environmental: -26° C to 54° C (-15° F to 130° F) with 5% to
95% non-condensing humidity
Contact Rating: .5A @ 125V AC/1A @ 30V DC
Maximum Current Draw Auxiliary 12V DC Output: 350mA
Minimum Loop Current: 15 mA
Minimum Ring Voltage: 40Vrms
Ringer Equivalence: 0.5 A REN
Connections: 10 pin screw terminal block
P
P
r
r
a
a
c
c
t
t
i
i
c
c
e
e
T
T
E
E
L
L
E
E
C
C
O
O
M
M
S
S
O
O
L
L
U
U
T
T
I
I
O
O
N
N
S
S
F
F
O
O
R
R
T
T
H
H
E
E
2
2
1
1
S
S
T
T
C
C
E
E
N
N
T
T
U
U
R
R
Y
Y
TECHNICAL
TECHNICAL
A
A
p
p
p
p
l
l
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
F
F
e
e
a
a
t
t
u
u
r
r
e
e
s
s
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
Vista de pagina 0
1 2 3 4

Indice de contenidos

Pagina 1 - TECHNICAL

LDB-2LDB-2Ring/LoopDetectorDecember 15, 2011The LDB-2 Ring/Loop Detector monitors an analog phone linefor ringing or an in-use condition. A built-in r

Pagina 2 - Diagram A Diagram B

A. MountingMountingHoles(2) #6 FlatheadScrews or SheetrockScrews (not included)Internal Viewof the LDB-2Diagram A Diagram BVIKING©MODEL: LDB-2Viking E

Pagina 3 - Internal View of the LDB-2

C. Ring Detection OnlyConnect the incoming line to terminal block positions 1 and 2, as shown in the diagram to the right. No terminal deviceis requir