11
DRAIN PLUMBING
Your ice machine uses a gravity drain that requires 5/8” (.63 cm) ID tubing from the back of the
ice maker to a plumbed connection to a sanitary sewer (see Gravity Drain drawing below).
Remove the access panel, with a 5/16” (0.8 cm) wrench to plumb in drain connection. Gravity
drain location for built-in units can be within the area shown in illustration below. An optional
drain pump can be purchased for your ice machine if a gravity drain is not accessible.
Observe and follow all local codes when installing an ice machine.
FFaaiilluurree ttoo uussee aaddeeqquuaattee
ddrraaiinnaaggee ssyysstteemm wwiillll rreessuulltt
iinn ssuurrrroouunnddiinngg wwaatteerr
ddaammaaggee aanndd//oorr ppoooorr iiccee
pprrood
duuccttiioonn..
WARNING
GRAVITY DRAIN LOCATION
TToopp ooff
UUnniitt
FFrroonntt ooff
UUnniitt
22” (55.9 cm)
24 5/8” (62.6 cm)
2 3/8” (6.0 cm)
4 1/16”
(10.3 cm)
14 3/4”
(37.5 cm)
6 3/4”
(17.1 cm)
GRAVITY DRAIN
DRAIN PUMP
Model Number - VUIM-DP
((SSoolldd sseeppaarraatteellyy -- sseeee iinnssttaallllaattiioonn
iinnssttrruuccttiioonnss ssuupppplliieedd wwiitthh ddrraaiinn
ppuummpp))
VENT TUBE GOES THRU THIS OPENING
IN THE ACCESS PANEL
DRAIN PUMP’S DISCHARGE
LINE THRU THIS OPENING
Comentarios a estos manuales