Viking FFI7240WL Manual de instalación

Busca en linea o descarga Manual de instalación para Neveras Viking FFI7240WL. Viking FFI7240WL Installation Instructions Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Installation
Guide
7 SERIES
Integrated All Refrigerator
Integrated All Freezer
VFI7180 / CVFI7180/ VFI7240 / CVFI7240
FFI7180 / CFFI7180 / FFI7240 / CFFI7240
MVFI7180 / CMVFI7180 / MVFI7240 / CMVFI7240
VRI7240 / CVRI7240
FRI7240 / CFRI7240
MVRI7240 / CMVRI7240
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - Installation

InstallationGuide7 SERIESIntegrated All RefrigeratorIntegrated All FreezerVFI7180 / CVFI7180/ VFI7240 / CVFI7240 FFI7180 / CFFI7180 / FFI7240 / CFFI

Pagina 2 - Table of Contents

10 Anti-Tip DimensionsWARNING TIP OVER HAZARD Appliance is top heavy and tips easily when not completely installed. To avoid a hazard due to insta

Pagina 3 - – Please Read and Follow!

11 General Information Area RequirementsVerify the following:• Unit can  t into residence and can be moved around corners and through doorways.

Pagina 4

12 General Information Water Supply Requirements (con't)• Connect 1/4” (6 mm)  exible copper tubing to household plumbing in compliance wit

Pagina 5 - Cutout Dimensions

13 Moving Unit Remove shipping brackets from skid by removing four bolts (two on each side) with a 1/2” (1.3 cm) deep-well socket wench and a pair of

Pagina 6 - Speci cations (VRI/FRI/MVRI)

14Optional Custom Front Panels - DimensionsNote: Overlay panel must be dry, solid, straight one-piece panels. The use of multiple panel pieces to achi

Pagina 7 - Integrated All Freezer

15Optional Custom Front Panels - InstallIn order to access the mounting holes, unsnap panel trim on both sides of door.Panel trimMounting Screw locati

Pagina 8 - Dimensions (VRI/FRI/MVRI)

16Water Line InstallationEnsure you have approximately 6 ft. (1.8 m) of 1/4" (6 mm) copper tubing available at the right rear side of the refri

Pagina 9 - Door Swing / Tipping Radius

17With the refrigerator in line with the cutout, but outside of the cabinetry, insert the copper tubing through the indicated hole.Push the copper tu

Pagina 10 - Anti-Tip Dimensions

18Leveling UnitOnce the unit is in position, height adjustment can be made from the front. Remove acess panel just below the water  lter. Using a 5/

Pagina 11 - General Information

19Flush Mount Side TrimAfter the unit has been placed in the cutout, leveled and all connections completed, the unit will need to be fastened to the c

Pagina 12 - Dual Installation

2Table of ContentsWarnings and Important Information ________________________________________________________________________________ 3 Cutout Dimensi

Pagina 13 - Moving Unit

20 Door Stop AdjustmentYour refrigerator is factory set at a 90o degree opening. The 90 degree door stop opening is shown in the illustration below w

Pagina 14 - Custom Panel - hole locations

21 Water Filter System Speci cation and Performance Data Sheet ContaminantReduction Average In uent NSF Speci ed Chal-lenge Concentration A

Pagina 15 - Mounting Screw

22 Performance Checklist —Verify cabinet size. — Verify electrical supply and water supply (if applicable). — Install anti-tip device(s) and v

Pagina 16 - Water Line Installation

23Service & Registration If service is required, call your authorized service agency. Have the following information readily available.• Model num

Pagina 17

Viking Range, LLC111 Front StreetGreenwood, Mississippi 38930 USA(662) 455-1200For product information,call 1-888-(845-4641)or visit our web site at

Pagina 18 - Kickplate Installation

3IMPORTANT – Please Read and Follow! • Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, fr

Pagina 19 - Door Panel Adjustments

4WARNING TIP OVER HAZARD Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely inst

Pagina 20 - degrees

5 Cutout Dimensions Can be located on either side84”(213.4 cm) min.opening height85-3/16”(216.3cm) max.opening height*Refer to Specficationchart fo

Pagina 21

6Speci cations (VRI/FRI/MVRI)Integrated All RefrigeratorDescription VRI MVRI 24" 24"Overall width 24" (61.0 cm) 24" (61.0 cm) Ove

Pagina 22 - Verify Operations

7Speci cations ( VFI/FFI/MVFI)Integrated All Freezer W/Custom PanelDescription FFI 18" 24"Overall width 18" (45.7 cm) 24" (61.0

Pagina 23 - Service & Registration

8 Dimensions (VRI/FRI/MVRI) Model Dimension A Dimension B*VRIVFI27-11/16" (70.3 cm) 24-3/4" (62.9 cm)FRI/FFIN/A 24" (61.0 cm)MVRI/MVFI

Pagina 24 - 062223-000 EN

9 Door Swing / Tipping Radius1050900AB18" 24"A 19-1/16" (48.4 cm) 25-3/16" (64.0 cm)B 20-1/16" (51.0 cm) 26-1/16" (66.2